The power supply recommended for AC powered installations where the observatory is located close to the AC power supply is the Meanwell GST120A12.

For observatories with heaters and long DC power cable runs the Meanwell HRP-300-12 is recommended as it’s remote sense functionality allows it to compensate for any voltage drop in the long cable runs. (If no heaters are present, the Meanwell HRP-150-12 is the preferred option.)

Direct links to order Meanwell HRP-300-12 from USA:

HRP-300-12, Mouser Electronics

HRP-300-12, TRC Electronics

Accessories for Meanwell HRP-300-12:

TRC-E-HRP300450600 enclosure for HRP-300-12

US/Canada power cord for HRP-300-12

Power_supply_wiring_with_remote_voltage_sense.svg

Outdoor Cable

The recommended off the shelf for use on roofs or outdoor structures is the sunlight and abrasion resistant AlphaWire EcoFlex PUR 80045 SL005 (unshielded) or 80145 SL005 (braid shield). Digi-Key usually has one or the other in stock: 80045 SL005, 80145 SL005.

That cabling doesn’t have a twisted pair, so we recommend wiring up the conductors to the green numbering in the two images below.

Recommended wiring on the power supply side for a 6 or 7 conductor cable (twisted pair will most likely not be present in off-the-shelf cables) You should use Blue 3mm Fork Crimps to terminate the conductors for L,N,E,-V and +V. This power supply should be installed in a metal enclosure which should be connected via grounding studs to the Earth terminal. The enclosure's door or access panel also needs to be connected. See the Meanwell HRP datasheet for sense connector details. Recommended wiring on the observatory power plug side for a 6 or 7 conductor cable (twisted pair will most likely not be present in off-the-shelf cables) Conductors 1 and 6 will need to be soldered to the side of C and B if thick conductors are used. The transition from insulated wire to contact needs to be covered by heat shrink to prevent short circuits if the cable subject to twisting torques.

Mathias Research Ranch Installation in Alberta, Canada

20190724_212110.jpg| 20190724_212620.jpg| 20190724_212709.jpg|

Long DC Cable Run Connector Care Package

If you need to build your own long cable with (using the cable listed above) you can request a Long DC Cable Run Connector Care Package from us. It should contain: Long_DC_cable_connector_care_package.png

Item #

Part

Quantity

Manufacturer

Manufacturer Part Number

Example Supplier Link 1

Example Supplier Link 2

1

MIL-DTL-5015 compatible plug, 14S-2S insert

1

various

(Amphenol Industrial)

various

(MS4106F-14S-2S-624)

https://www.digikey.com/product-detail/en/amphenol-industrial-operations/MS3106F-14S-2S/MS3106F14S-2S-ND/378649

https://au.rs-online.com/web/p/mil-spec-circular-connectors/2982465/

2

PG13.5 cable gland adaptor for size 14 MIL-DTL-5015 compatible plug

1

Amphenol Industrial

97B-14S-PG13.5-624

DFN Camera Help

Amphenol Industrial (minimum order quantity will apply)

3

PG13.5 cable gland

1

various

various

https://www.digikey.com/products/en/cables-wires-management/cable-and-cord-grips/492?k=&pkeyword=&sv=0&pv121=385758&pv121=385768&sf=1&FV=-8%7C492&quantity=&ColumnSort=0&page=1&pageSize=25

https://www.altronics.com.au/p/h4318A-6-12mm-eg13.5-pg13.5-black-ip68-cable-gland/

4

≈10mm length of 3 mm yellow heatshrink tubing

2

various

various

https://www.altronics.com.au/p/w0912a-black-3mm-heatshrink-1.2m-length/

5

≈10mm length of 3 mm black heatshrink tubing

2

various

various

https://www.altronics.com.au/p/w0912a-black-3mm-heatshrink-1.2m-length/

6

≈10mm length of 5 mm heatshrink tubing (may be required if 3 mm tubing doesn't fit over contacts "C" and "B")

0-2

various

various

https://www.altronics.com.au/p/w0913a-black-5mm-heatshrink-1.2m-length/

7

Power supply connector

1

Hirose

DF11-2DS-2C

https://www.digikey.com.au/product-detail/en/hirose-electric-co-ltd/DF11-8DS-2C/H2022-ND/141255

8

≈10mm length of 3 mm heatshrink tubing

2

various

various

https://www.altronics.com.au/p/w0912a-black-3mm-heatshrink-1.2m-length/

9

≈10mm length of 1.5 mm heatshrink tubing

2

various

various

https://www.altronics.com.au/p/w0910a-black-1.5mm-heatshrink-1.2m-length/

10

DF-11 pre crimped jumper cable, red, cut in half

1

Hirose

H3BBT-10106-R6

https://www.digikey.com.au/product-detail/en/hirose-electric-co-ltd/H3BBT-10106-R6/H3BBT-10106-R6-ND/310537

11

DF-11 pre crimped jumper cable, black, cut in half

1

Hirose

H3BBT-10106-B6

https://www.digikey.com.au/product-detail/en/hirose-electric-co-ltd/H3BBT-10106-B6/H3BBT-10106-B6-ND/310505

12

Blue 4 mm fork crimp terminal

7

various

various

https://www.altronics.com.au/p/h2082a-blue-4mm-fork-crimp-pk-100/

Long DC Cable Assembly

20190918_114454.jpg 20190918_114512.jpg 20190918_114635.jpg 20190918_114658.jpg 20190918_115321.jpg 20190918_115757.jpg 20190918_115538.jpg 20190918_115612.jpg 20190918_115724.jpg 20190918_115806.jpg 20190918_115819.jpg 20190918_115836.jpg 20190918_115848.jpg 20190918_120819.jpg 20190918_122415.jpg 20190918_122350.jpg 20190918_120735.jpg 20190918_122718.jpg 20190918_121758.jpg 20190918_123025.jpg 20190918_123050.jpg 20190918_122938.jpg 20190918_123119.jpg 20190918_123215.jpg 20190918_123318.jpg 20190918_123427.jpg 20190918_123442.jpg

Your connector should now look like this:

20190918_123513.jpg| 20190918_123550.jpg| 20190918_123612.jpg|

20190918_123625.jpg 20190918_123725.jpg 20190918_123729.jpg 20190918_123756.jpg 20190918_123806.jpg 20190918_124546.jpg 20190918_124546.jpg 20190918_124812.jpg

20190918_140828.jpg 20190918_140939.jpg

20190918_125003.jpg 20190918_124842.jpg 20190918_125102.jpg 20190918_135624.jpg 20190918_135630.jpg 20190918_135819.jpg 20190918_140019.jpg 20190918_140158.jpg 20190918_140254.jpg 20190918_140334.jpg 20190918_140355.jpg 20190918_140948.jpg

add df 11 stuff

20190918_141031.jpg